Tatarek - controller for heating systems RT-08G Solar Buffer

manufacturer: Tatarek

Category: Control, automation

product #: 33281

Order multiples of: 1 Add to cart

Add to wish list Ask about product Report an error in description Installment purchase is available from 100 PLN of product value or the entire order. Leasing is available from PLN 369 of the value of the product

Price on request

price-list
net unit price
1 276,00zł
for item
discount price
net unit price
915,00zł
for item
minimum trading quantity
the amount of product
1.00 item
unit
trading
1.00 item
total price
net list price
1 276,00zł
for 1.00 item
total price
discounted net price
915,00zł
for 1.00 item
price-list
gross unit price
1 569,48zł
for item
discount price
gross unit price
1 125,45zł
for item
minimum trading quantity
the amount of product
1.00 item
unit
trading
1.00 item
total price
gross list price
1 569,48zł
for 1.00 item
total price
gross discount price
1 125,45zł
for 1.00 item

Product description

Control set with graphic display. It is used to operate the heating system supplied from a fireplace with a water jacket, with regulation of the air supply to the combustion chamber by means of a cold air damper. Provides automatic operation of the buffer loading pump. It also allows heat distribution via a circulation pump to the central heating system. The controller also allows operation of the solar collector pump supplying buffer. A voltage free contact allows you to switch on or off another device (e.g. gas oven).

Equipment

  • three water temperature sensors
  • air supply damper
  • mounting box for concealed installation
  • Titanium Design version
  • graphic display

Basic controller functions

  • smooth control of the throttle regulating combustion air supply
  • optimization of the combustion process in the fireplace
  • control of the charging pump operation Buffer
  • circulation pump control
  • controlling solar pump operation
  • various modes of operation for the central heating pump
  • the function of blocking another source of heat when the fireplace provides heat to the installation
  • integrated zone thermostat function
  • memory in case of power failure - restoration of previously made settings

Technical data

  • 230 V / 50 Hz power supply
  • no load power consumption 5 W
  • maximum connected power 750 W
  • number of outputs controlling 3 * 250 W / 230 V / 50 Hz pumps
  • one voltage-free control output
  • number of outputs controlling the throttle drive 1 * 5 V / 500 mA / DC
  • quantity sensor in water temperature 3 * PT1000 (-50 ... + 200 C)
  • accuracy of temperature measurement 2 C
  • temperature measurement resolution 0.5 C